Fujitsu FR81S User Manual

Page of 2342
CHAPTER 23: 32-BIT INPUT CAPTURE 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 32-BIT INPUT CAPTURE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
11 
4.4.  Cycle Measurement Data Register : MSCY 
This section shows the cycle measurement data register. 
This register is used to store the cycle measured data value, when an effective edge of the corresponding 
external input pin signal was detected. 
 MSCY4 (Input capture 4): Address 0118
H
 (Access: Half-word, Word) 
 MSCY5 (Input capture 5): Address 011C
H
 (Access: Half-word, Word) 
 MSCY6 (Input capture 6): Address 0F68
H
 (Access: Half-word, Word) 
 MSCY7 (Input capture 7): Address 0F6C
H
 (Access: Half-word, Word) 
 MSCY8 (Input capture 8): Address 0FF4
H
 (Access: Half-word, Word) 
 MSCY9 (Input capture 9): Address 0FF8
H
 (Access: Half-word, Word) 
 
bit31 
 
 
 
 
 
 
bit0 
 
 
 
 
 
CY[31:0] 
 
 
 
Initial value  XXXX 
XXXX 
XXXX 
XXXX 
XXXX 
XXXX 
XXXX 
XXXX 
Attribute 
 
 
 
R,WX 
 
 
 
 
When MSCL.MSCn(n=4-9) is 0, "0000_0000
 H
 " is set in this register. 
When MSCL.MSCn(n=4-9) is 1, the cycle value when the edge is detected is set in this register. 
Note: 
Please use the half-word or the word access instruction for this register. Moreover, data cannot be written in 
this register. 
 
MB91520 Series
MN705-00010-1v0-E
886