CHAPTER 24: 16-BIT FREE-RUN TIMER 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : 16-BIT FREE-RUN TIMER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
14 
4.2.2. 
Timer Data Register : TCDT0 to TCDT2 
The timer data register (TCDT) is used for reading the count value of the 16-bit free-run timer. It is also 
possible to set the count value of the 16-bit free-run timer. 
  TCDT0: Address 1206
H
 (Access: Half-word, Word) 
  TCDT1: Address 120E
H
 (Access: Half-word, Word) 
  TCDT2: Address 1216
H
 (Access: Half-word, Word) 
 
bit15 
bit14 
bit13 
bit12 
bit11 
bit10 
bit9 
bit8 
 
T15 
T14 
T13 
T12 
T11 
T10 
T09 
T08 
Initial value 
Attribute 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
 
 
 
 
 
 
 
 
 
 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
T07 
T06 
T05 
T04 
T03 
T02 
T01 
T00 
Initial value 
Attribute 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
 
[bit15 to bit0] T15 to T00: Count value bits 
T15 to T00 
Function 
Count value 
 
 
The timer data register is used for reading the count value of the 16-bit free-run timer. 
 
The count value will be cleared to "0000
H
" as soon as reset occurs. 
 
The timer value can be set by writing a value to this register. However, a value needs to be written while the 
timer is inactive (STOP:bit22 of timer state control register (TCCS) is 1). 
 
The 16-bit free-run timer will be initialized as soon as any of the following occurs. 
- Reset 
- While the 16-bit free-run timer is active (STOP:bit22 of timer state control register (TCCS) is 0), the 
clear bit (SCLR:bit20) of the timer state control register (TCCS) is 1 
- The timer count value matches the compare clear register in the up-count mode (MODE: bit21 of 
timer state control register (TCCS) is 0) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MB91520 Series
MN705-00010-1v0-E
921