Fujitsu C122-E177-01EN User Manual

Page of 512
MMB Web-UI (Web User Interface) Operations 
 
1.2.10 [Power Supply] window 
[Power Supply] window displays the PSU status in the PRIMEQUEST 2000 series.  
Once the error in the status of each PSU is detected, the abnormality status is maintained till the PSU is 
replaced or the abnormality status is cleared by clicking the [Status Clear] button. 
 
FIGURE 1.14 [Power Supply] Window 
 
 
TABLE 1.38 Display Item on [Power Supply] Window 
Items 
Description 
System Power Status 
Displays the power supply status of PRIMEQUEST 2000 series system (chassis) 
· 
On 
· 
Standby 
Power Supply 
Redundancy 
Displays redundancy status of PSU/FANU.  
· 
Redundant: In case of the PSU is redundant. 
· 
Non-redundant: Sufficient Resources: When there is a PSU which is 
required to operate the system even if redundancy of the PSU is lost.  
· 
Non-redundant: Insufficient Resources: When redundancy of the PSU is 
lost, and when there is no PSU which is required for operating the system. 
PSU Status 
Displays the status of PSU/FANU 
· 
OK 
· 
Not-present 
· 
Failed 
· 
A/C Lost 
· 
Configuration error 
· 
- (When Type is FANU) 
PSU Power Status 
Displays power supply ON/OFF status of PSU/FANU