Fujitsu GranPower7000 (GP 7000F) User Manual

Page of 199
CHAPTER 3 M200R Main Cabinet
Example for normal operation
 === Memory ===================
 Type : SDRAM
 SLOT#       Size [ Valid (MB) / Existing (MB) ]                Total
 00- 0- 3    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 00- 4- 7    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 00- 8-11    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 00-12-15    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 * = Error SLOT
Example of a slot
#
4 error
 === Memory ===================
 Type : SDRAM
 SLOT#       Size [ Valid (MB) / Existing (MB) ]                Total
 00- 0- 3    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 00- 4- 7      0 /   0*    0 / 256     0 / 256     0 / 256    :    0 / 768 MB
 00- 8-11    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 00-12-15    256 / 256   256 / 256   256 / 256   256 / 256    : 1024 / 1024 MB
 * = Error SLOT
Note:
If a memory error is detected, an asterisk is displayed in the Size field for the
corresponding slot. In this example, an error in slot
#
4 is detected in the initial
diagnostics operation. Modules in slots 5 to 7 are recognized as normal modules but
also become invalid.
3.4
Disk Units
Disk drive configuration
Up to 2 disk drives can be installed in the base configuration of the M200R main cabinet. To install
more than 3 disk drive units, the Expansion File Unit must also installed.
34