2. Go offline if the SSS is not already offline.
3. Change the PC setting for the SSS to the C200HX/HG/HE.
4. If you want to transfer I/O comments together with the program to the
C200HX/HG/HE, allocate UM area for I/O comments.
5. Allocate expansion DM words DM 7000 to DM 7999 in the UM area using the
UM allocation operation from the SSS.
6. Copy DM 1000 through DM 1999 to DM 7000 through DM 7999.
7. Write “0100” to DM 6602 to automatically transfer the contents of DM 7000
through DM 7999 to DM 1000 through DM 1999 at startup.
8. To transfer to an EEPROM Memory Cassette, use the following procedure.
a) Connect the SSS to the C200HX/HG/HE and go online.
b) Make sure that pin 1 on the C200HX/HG/HE’s CPU Unit is OFF to enable
writing to the UM area.
c) Transfer the program and any other require data to the C200HX/HG/HE.
You will probably want to transfer DM data and the I/O table, if you have
created an I/O table for the C200H. Make sure you specify transfer of the
Expansion DM Area and, if desired, the I/O Comment Area.
d) Turn ON SR 27000 from the SSS to transfer UM data to the Memory Cas-
sette and continue from step 9.
or
To transfer to an EPROM Memory Cassette, use the following procedure.
a) Connect a PROM Writer to the SSS and write the data to the EPROM
chip using the SSS EPROM writing operation.
b) Set the ROM type selector on the Memory Cassette to the correct capac-
ity.
c) Mount the ROM chip to the Memory Cassette.
d) Mount a EPROM Memory Cassette to the C200HX/HG/HE.
9. Turn ON pin 2 on the C200HX/HG/HE’s DIP switch to enable automatic
transfer of Memory Cassette data to the CPU Unit at startup.
10. Turn OFF the C200HX/HG/HE and then back ON to reset it and transfer
data from the Memory Cassette to the CPU Unit.
11. Test program execution before attempting actual operation.
C200HX/HG/HE Features