2.13.3 Reset (CN18)
Many computer cases offer the convenience of a reset button. Connect the 
wire from the reset button
2.13.4 HDD LED (CN19)
You can connect an LED to connector CN19 to indicate when the HDD is 
active.
2.13.5 ATX soft power switch (CN21)
If your computer case is equipped with an ATX power supply, you should 
connect the power on/off button on your computer case to CN21. This 
connection enables you to turn your computer on and off.
2.14  ATX Power Control Connectors (CN20 and 21)
1RWH5HIHUWRWKHGLDJUDPRQWKHSUHYLRXVSDJHIRUWKHORFDWLRQ
RI&1
2.14.1 ATX feature connector (CN20) and soft power 
switch connector (CN21)
The PCA-6186 can support an advanced soft power switch function if an 
ATX power supply is used. To enable the soft power switch function:
1.
Take the specially designed ATX-to-PS/2 power cable out of the 
PCA-6186's accessory bag.
1
1
       CN20