1.8.4 COM2 RS 232/422/485 mode selector (J2) 
Users can use J2 to select among RS 232/422/485 modes for COM2. 
The default setting is RS 232. 
 
 
 
 
 
 
Table 1.6: COM2 RS 232/422/485 mode selector (J2) 
 
Function 
Jumper Setting 
RS232 
(5-6) + (7-9) + (8-10) + (13-15) + (14-16) closed 
RS422 
(3-4) + (9-11) + (10-12) + (15-17) + (16-18) closed 
RS485 
(1-2) + (9-11) + (10-12) + (15-17) + (16-18) closed 
 
 
 
1.8.5 LVDS Power 3.3V/5V selector (J6) 
 
Table 1.7: LVDS Power 3.3V/5V selector (J6) 
 
Function 
Jumper Setting 
 
5V 
 
1-2 closed 
 
*3.3V 
2-3 closed 
 
*default setting