Advantech MIC-3043 User Manual

Page of 58
19
Chapter 3  
•  Complies with CompactPCI Front-Access Power Connectors PICMG 
2.11, R3.0.
•  Complies with CompactPCI Computer Telephony PICMG2.5, R1.0 
(optional)
•  Dimensions: 440 x 177 x 320 mm (17.3" x 7" x 12.6")
•  Operating temperature: 0° C ~ 45° C 
3.4  Slot Assignments
The CompactPCI specification defines slot numbering separation for 
physical and logical slots. Each slot has a physical number and a logical 
number (refer to the CompactPCI specification version 2.0 R3.0 for fur-
ther information on slot assignments). The physical numbers are printed 
on the backplane, enclosed in circles or triangles. Slot5 of MIC-3811 and 
MIC-3812, marked by a triangle, is the system slot and can only be used 
by a CPU board. The other slots are peripheral slots. The logical number 
of each slot is defined according to the IDSEL signal and the associated 
address used to select the slot. Table 3-1 shows the system slot and 
peripheral slot relationships on the backplane. The system slot has a logi-
cal number of 5, and peripheral slots have logical numbers of 1~4, and 6. 
The connectors in logical slot 1 are designated as 1-P1, 1-P2, and 1-P3 
from the bottom up. Nomenclature for connectors in the other slot is sim-
ilar, such as 2-P1 and 2-P2.
Connector S5P1 on the system slot (slot 5) is a keyed connector providing 
a 32-bit CompactPCI bus between the system slot and the peripheral slot. 
Connector S5P2 on the system slot (slot 5) is an un-keyed connector pro-
viding 64-bit CompactPCI bus between the system slot and the peripheral 
slots. Connector S5P3 on the system slot (slot 5) is open for user defini-
tion. The pin assignment of connector S5P4 and S5P5 is only for H.110 
CT bus support with MIC-3043A and MIC-3043C.  For MIC-3043B, 
they are open for user definition.
Please check appendix A for the pin assignment of all connectors on the 
backplane.