Adaptec 1430SA User Manual

Page of 103
Appendix D: Using the Adaptec Flash Utility for DOS
84
A:\> AFU SAVE /C 0
In the following example, the AFU saves flash contents from Controller 1 to a UFI file in 
C:\UFI_FILES.
A:\> AFU SAVE /C 1 /D C:\UFI_FILES
UPDATE
The 
UPDATE
 command updates a HostRAID controller’s flash components from the flash image 
data in a UFI file. You can use the 
UPDATE
 command to update a single HostRAID controller’s 
flash components or to update multiple HostRAID controllers on your computer.
You must restart the computer following an 
UPDATE
 command.
Command Syntax
The command syntax for the 
UPDATE
 command is as follows:
AFU UPDATE [/C<
Controller ID
>] [/D <
UFI File Path
>]
Command Switches
For details on the /C and /D switches, see 
Examples
The following example shows a typical system response after an update has been performed:
A:\> AFU UPDATE /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Updating Controller 0 (Adaptec ASC-48300)
Reading flash image file (Build 1406)
AFU is about to update firmware on controller(s) Adaptec ASC-48300
***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***
This might take a few minutes.
Writing Adaptec ASC-48300 (4MB) Flash Image to controller 0...OK. 
Verifying...OK
Please restart the computer to allow firmware changes to take effect.
VERIFY
The 
VERIFY
 command compares the contents of each of the flash components on a HostRAID 
controller to the corresponding image in a UFI file and indicates whether they match. Use this 
command to determine whether a HostRAID controller’s flash components are up-to-date 
when compared to a specific UFI file.
Command Syntax
The command syntax for the 
VERIFY
 command is as follows:
AFU VERIFY [/C<
Controller ID
>] [/D <
UFI File Path
>]
Command Switches
For details on the /C and /D switches, see