Chapter 2. CLI Syntax Reference
62
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
/c
x
/u
x
 set identify=on|off
This feature only applies to 9550SX and 9590SE model controllers.
This command allows you to identify a unit within an enclosure. 
When that the EPCT (Enclosure Port Configuration Table) equates identify 
with blinking, as it does in the 3ware Sidecar Enclosure, the LEDs associated 
with the drive slots of the specified unit blink. 
Example:
 //localhost> /c0/u0 set identify=on
 Sending Identify request for unit /c0/u0 to [on] ... Done.
/c
x
/u
x
 set ignoreECC=on|off
This feature only applies to 9000 series controllers.
This command allows you to set the ignoreECC policy for a given unit.
When ignoreECC policy is set to off, if a rebuild process encounters bad 
sectors on the source disk, the rebuild will fail. When ignoreECC is set to on
such errors are ignored, and the rebuild will continue. When you use 
ignoreECC, a file system check is recommended following the rebuild, to 
insure data integrity.
By default, ignoreECC is off.
/c
x
/u
x
 set name=
string
This command allows you to name the unit with an arbitrary name. You can 
use this name in conjunction with the unit serial number to cross-reference 
with the unit. The system does not check to ensure uniqueness of names, so be 
careful to assign different names to each unit.
                                      
/c
x
/u
x
 set qpolicy=on|off 
This command applies only to 9550SX and 9590SE controllers.
This command sets the queue policy of the firmware. If the queue policy is 
on, the firmware utilizes the drive queueing policy. If some of the drives in 
the unit do not support any queueing policy, this policy will have no effect on 
those drives. 
Note:
 The unit’s serial number is automatically assigned when the unit is created 
and is not changeable.