AMCC 9590SE-4ME User Manual

Page of 93
Port Object Commands
www.3ware.com 
71
/c
x
/p
x
 show ncq
This command applies only to 9550SX and 9590SE model controllers.
This command displays the NCQ (Native Command Queueing) information 
for the drive attached to the specified port, including whether NCQ is 
supported by the drive, and whether it is enabled at the drive.
For queuing to be used, it must be enabled for the unit and supported by the 
drive. 
Example:
//localhost> /c0/p5 show ncq
 /c0/p5 NCQ Supported = No
 /c0/p5 NCQ Enabled = No
/c
x
/p
x
 show lspeed
This command applies only to 9550SX and 9590SE model controllers.
This command displays the maximum SATA link speed supported by the 
drive attached to the port and the present SATA link speed setting.
Example:
//localhost> /c0/p5 show lspeed
 /c0/p5 SATA Link Speed Supported = 3.0 Gb/s
 /c0/p5 SATA Link Speed = 3.0 Gb/s
/c
x
/p
x
 show capacity
This command displays the capacity of the drive attached to the specified port 
in two formats—GB and blocks. Note that of this version, the GB format is 
computed based on division by 1000 (not 1024). 
Example:
 //localhost> /c0/p5 show capacity
 149.05 GB (312581808)
/c
x
/p
x
 show smart
This command extracts SMART (Self Monitoring Analysis and Reporting) 
data from the specified disk. Because the data is extracted live from the disk, 
this command can be used to get the most recent data about the presence or 
absence of a disk.
The SMART data is displayed in hexadecimal form.