AMCC 9590SE-4ME User Manual

Page of 93
Chapter 2. CLI Syntax Reference
82
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
/e
x
/slot
x
 show identify
This command shows the identify status of the specified slot. The status can 
be either on or off.
Example:
//localhost> /e0/slot1 show identify
/e0/slot1 Identify status = on
/e
x
/slot
x
 set identify=on|off
This command causes the slot to be identified by blinking the LED associated 
with it, or turns off identification of the LED for this slot. 
Setting identify to on will cause the LED associated with that slot to blink, 
provided that the EPCT has been set to associate “identify” with “blinking,” 
as is the case in the 3ware Sidecar. 
Note:
 This command is equivalent to “/cx/px set identify=on|off” on page 73
Example:
//localhost> /e0/slot1 set identify=on
Sending Identify request to Drive Slot /e0/slot0 to [on] ... 
Done.
/e
x
/fan
x
 show
This command shows the information about the specified fan element /fanx in 
the specified enclosure /ex. The fan name is followed by its status. If a fan is 
on and no fault has been detected, the status would indicate OK.
Example:
 //localhost> /e0/fan0 show
 Fan       Status    
 -------------------          
 fan0      OK
/e
x
/temp
x
 show
This command shows the information about the specified temperature sensor 
element /fanx in the specified enclosure /ex. The temperature sensor name is 
followed by the temperature sensed in the enclosure unit. 
Example:
 //localhost> /e0/temp0 show
 TempSensor       Temperature 
 -------------------------------
 temp0            24~C(75~F)