Epson RX-8581JE User Manual

Page of 32
RX
    
-
    
8581
        
SA
    
/
    
JE
    
/
    
NB
 
 
 
Page - 8 
MQ372-02
 
 
4) STOP bit 
This bit is used to stop functions related to the RTC's internal counter operations.   
Writing a "1" to this bit stops the counter operations.   
Writing a "0" to this bit cancels stop status (restarts operations).   
 For optimum performance, do not use this bit for functions other than the clock and calendar functions.   
STOP 
Data Description 
[Normal operation mode] 
 
This bit is used to cancel stop status for (i.e., restart) the clock and calendar 
function. Also, when "1" is written to the STOP bit, it cancels stop status for 
the fixed-cycle timer function.   
 ∗ 
When the RESET bit value is "1" operation will not be restarted. To restart operation, a "0" must 
be written to both the STOP bit and the RESET bit. 
 
Write/Read
[Operation stop mode] 
 
Stops updating of year, month, date, day, hour, minute, and second values 
and partially stops the fixed-cycle timer function. 
 
(Stop 1) Stops updating of year, month, date, day, hour, minute, and 
second values   
• This stops all clock and calendar update operations.   
Once this occurs, no more time update interrupt events or    alarm 
interrupt events occur.   
 
(Stop 2) Partially stops the fixed-cycle timer function 
• If the fixed-cycle timer's source clock settings include an update 
setting of 64
 
Hz, 1
 
Hz, or "Minute", the fixed-cycle timer function does 
not operate.   
 
However, this function does operate 
when the fixed-cycle timer's source 
clock setting is 4096
 
Hz.  
 
When this bit value is "1", internal divider stops from 2048Hz to 1 Hz . 
 
 
5) RESET bit 
Like the STOP function described above, this function stops functions related to counter operations. It also 
resets the RTC module's internal counter value when the value is less than one second.   
Writing a "1" to this bit stops the counter operation and resets the RTC module's internal counter value when the 
value is less than one second.   
 
Writing a "0"
 
to this bit cancels stop status for (restarts) these operations. If a STOP condition or repeated 
START condition is received while the 0.95-second bus timeout function is operating, stop status is automatically 
canceled (the
 
RESET bit value is changed from "1"
 
to "0").   
 For optimum performance, do not use this bit for functions other than the clock and calendar functions.   
 
RESET 
Data Description 
[Normal operation mode] 
 
This bit is used to cancel stop status for (i.e., restart) the clock and calendar 
function. Also, when "1" is written to the RESET bit, it cancels stop status for 
the fixed-cycle timer function.   
 ∗ 
Since operation is not restarted when the STOP bit value is "1", to restart operation, a "0" must be 
written to both the STOP bit and the RESET bit. 
 
Write/Read
[Operation stop mode] 
 
Stops updating of year, month, date, day, hour, minute, and second values 
and partially stops the fixed-cycle timer function. 
 
(Stop 1) Stops updating of year, month, date, day, hour, minute, and 
second values   
• This stops all clock and calendar update operations.   
Once this occurs, no more time update interrupt events or alarm 
interrupt events occur.   
 
 
(Stop 2) Partially stops the fixed-cycle timer function 
• If the fixed-cycle timer's source clock settings include an update 
setting of 64
 
Hz, 1
 
Hz, or "Minute", the fixed-cycle timer function does 
not operate.   
 
However, this function does operate when the fixed-cycle timer's source clock setting is 
4096
 
Hz.  
 
(Note) When this bit value is "1", the internal divider keeps the reset state, from 2048Hz to 1 Hz .