Symmetricom 1100 User Manual

Page of 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 131
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Sample Command
ED-SYNC::SYS:TS1000::CLRDELAY=5;
This command declares a faulted input to be valid five seconds after the alarm 
condition has cleared.
Autonomous Message
TP-SSU 03-10-24 11:18:00
A 1192 REPT EVT
“SYS,EQPT:NA,CLRDELAY,NSA,03-10-24 11-18-00:\"INPUT CLEAR 
DELAY HAS CHANGED\””
;
Retrieving Current Alarm Settings
You can display the current settings for any alarm using the RTRV-ATTR command.
RTRV-ATTR:[<tid>]:<aid>:[<ctag>][::<keyword>];
This command always has an access level of USER.
SYS 
(cont’d)
GPSCLRDEL
0 to 1000 s
Sets the time delay to 
declare GPS is valid after 
an alarm condition clears
5
GPSFLTDEL
1 to 1000 s
Sets the time delay before a 
GPS fault is declared
1
<aid>
<keyword>
Description
SYS
ELEVTIME
ENABLE | DISABLE
SYS
IMC
IOC
PRS
INPp (p = 1 | 2)
Alarm ID
The Alarm ID is described in 
ALL (or null)
ALL (or null)
Returns all of the alarm attributes
<aid>
<keyword>
<value>
Description
Default value