Symmetricom 1100 User Manual

Page of 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 149
Chapter 5 Testing the TimeProvider
Testing Alarm Conditions
Testing the Reference Switching
To test the ability of the TimeProvider to switch references, you perform a two-step 
test:
Connect appropriate reference inputs to the TimeProvider.
Create a fault on the selected reference signal and observe that the 
TimeProvider changes to the appropriate secondary input.
To test the reference switching:
1. Connect a suitable reference signal to the PRS input and a second reference 
signal to the INP1 input. Wait for the Qualified LEDs for both inputs to turn green 
and for the Active LED to light on the PRS input.
2. Issue the 
ED-EQPT::PRS:::INSTATE=DISABLE;
 command to disable the PRS 
input and force the TimeProvider to switch to the INP1 reference. 
3. Observe that the Active LED changes from the original input to the secondary 
input (PRS to INP1 or INP1 to PRS).
Testing the Non-Revertive Operating Mode
When the TimeProvider is in the non-revertive operating mode, the input reference 
signal does not revert to the original input after it recovers from an error condition.
The TimeProvider is in non-revertive mode when the QLEVEL parameter for INP1, 
INP2, and PRS inputs is set to the same value, and the PRIORITY parameters for 
the same inputs are set to the same level.
To test the non-revertive operating mode, perform the following steps:
1. Define the non-revertive mode by setting the QLEVEL and PRIORITY 
parameters to appropriate values. See 
, on page 113, for further information.
2. Provision and connect appropriate reference inputs to the TimeProvider.
3. Create a fault on the selected reference signal and observe that the 
TimeProvider changes to the appropriate secondary input.
4. Remove the fault on the initial reference signal and observe that the 
TimeProvider does not revert to that initial reference input. The event log 
indicates that the reference signal is no longer in fault.