TimeProvider User’s Guide 163
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Diagnosing the IMC
Interpreting Error Messages
Error messages appear on the console as they occur, and include the time and date 
of occurrence. Refer to the event codes described in 
 and to the alarm 
codes described in 
Replacing the IMC or IMC/TPIU
You can remove the IMC or the IMC/TPIU from the shelf and replace it without 
affecting outputs. 
1. Save the contents of the IMC memory in an IOC by issuing the following 
command:
CPY-MEM:::::IMC,IOC,IMC;
This command may take more than two seconds to execute; if it does, then the 
In-Process response is issued. See the TimeProvider TL1 Reference Guide for 
more information on the CPY-MEM command.
2. Attach a wrist grounding strap and connect it to the TimeProvider chassis.
3. Remove the IMC by loosening the captive screws and pulling the IMC from the 
shelf using the U-shaped handles. 
Major
Red
Off
Major system alarm
No alarm
Minor
Yellow
Off
Minor system alarm
No alarm
Alarm Cutoff (ACO)
Green
Off
On
Off
Antenna Power 
(IMC/TPIU only)
Green
Red
Off
Internal TPIU is communicating with Antenna 
Internal TPIU has lost communication with Antenna
GPS is disabled
Antenna Signal 
(IMC/TPIU only)
Green
Red
Off
Antenna is communicating with the internal TPIU
Master shelf is powering up
Antenna has lost communication with the internal TPIU
Warning: To avoid possible electrostatic damage to the IMC, 
place it in a static-free bag or on a static-free surface.