7.
1 Explaining Basic Cy
cles
Dwell:
Dwell (G4) can be used to program a delay between blocks. A Timed 
Dwell is a timed stop. An Infinite Dwell is a stop that can be canceled 
only by pressing START. With a dwell activated, the 3500i halts 
motions on all axes, but other functions (coolant on/off, spindle 
control) remain active. Do not program any other commands.
The time countdown is displayed in the Machine Status Area of the 
Manual Data Input, and Program Run screens.
Select the More Milling button, and then "Dwell" from 
the pop-up menu.
Conversational format: Dwell 15 (hold for 15 seconds), or Dwell 0 
(hold infinitely).
G-code format: G4 T15 (hold for 15 seconds), or G4 T0 (hold 
infinitely)
It is recommended that the Programmed Stop M-function 
(M00) be used instead of an infinite dwell.
Field
Code
Description
Dwell
T
Amount of time in seconds to halt 
movement and program execution. 
Acceptable range of 0.1 to 9999.9 seconds. 
Enter a value of 0 for an infinite hold. 
(Required)