Acu-Rite CNC 3500i User Manual

Page of 472
206
7 Programming: Canned Cycles, sub-programs
7.
3 Pr
obing Cy
cles
Format: G151 T(tool#) D (tool rough diameter)
With T and D cycle parameter only set:
The machine rapids the Z-axis up, picks up the tool designated in the 
T cycle parameter, and rapids directly over the center of the probe 
stylus.
The Z-axis rapids down the distance placed in the 
ZRapidToStartPositionFromHome machine setup parameter then 
starts feeding down toward the probe for the initial touch at the 
feedrate that was placed in the ZFirstPickFeedRate_Fast machine 
setup parameter, then backs up.
The machine rapids over half the diameter of the cutter from the 
probe stylus center in the direction related to the probeOrientation 
machine setup parameter.
The spindle then comes on in reverse at the RPM specified in the 
calibAndToolMeasurementRPM machine setup parameter and 
retouches the probe twice, once at the feedrate that is in the 
ZFirstPickFeedRate_Medium machine setup parameter and again at 
the ZFirstPickFeedRate_Slow machine setup parameter.  
ZFirstPickFeedRate_Medium machine setup parameter and again at 
the ZFirstPickFeedRate_Slow machine setup parameter.
The tool-length register for that tool is now updated, and any value 
in the length wear register is reset to zero.
Then the Z-axis rapids up to the home position.
If you have done a single tool in Manual, that tool is now measured 
and you are ready to measure the next tool. If you have placed 
multiple lines in a program, one for each tool, the machine then 
grabs the next tool and repeats steps 1 through 6 until all the tools 
have been measured.