Acu-Rite CNC 3500i User Manual

Page of 472
ACU-RITE 3500i
209
7.
3 Pr
obing Cy
cles
Field
Code
Description
OvrSlw
Feed
S
This is the override for the slow feedrate 
that was set in the machine setup 
parameter ZFirstPickFeedRate_Slow. This 
is used for the same reason as the M cycle 
parameter. This can only be set slower. 
Trying to set this higher will result in the 
software using the original feedrate. 
(Optional)
OvrRPM
R
This is the override for the RPM that was 
set in the machine setup parameter 
calibAndToolMeasurementRPM. This is 
used for the same reason as the M cycle 
parameter. This can only be set slower. 
Trying to set this higher will result in the 
software using the original RPM. If you 
would like the cycle to run without the 
spindle turning, enter a negative value in 