Tektronix TDS 500C User Manual

Page of 352
Measuring Waveforms
3–116
TDS 500C, TDS 600B, & TDS 700C User Manual
Table 3–10: Measurement definitions (cont.)
Name
Definition
Phase
Timing measurement. The amount one waveform leads or lags another in time. Expressed in
degrees, where 360
 comprise one waveform cycle.
Period
Timing measurement. Time it takes for the first complete signal cycle to happen in the waveform
or gated region. The reciprocal of frequency. Measured in seconds.
Positive Duty Cycle
Timing measurement of the first cycle in the waveform or gated region. The ratio of the positive
pulse width to the signal period expressed as a percentage.
PositiveDutyCycle
PositiveWidth
Period
  100%
Positive Overshoot
Voltage measurement over the entire waveform or gated region.
PositiveOvershoot
+
Max
High
Amplitude
  100%
Positive Width
Timing measurement of the first pulse in the waveform or gated region. The distance (time)
between MidRef (default 50%) amplitude points of a positive pulse.
Rise time
Timing measurement. Time taken for the leading edge of the first pulse in the waveform or
gated region to rise from a Low Ref value (default = 10%) to a High Ref value (default = 90%) of
its final value.
RMS
Voltage measurement. The true Root Mean Square voltage over the entire waveform or gated
region.
Extinction Ratio
Optical measurement. The value High/Low.
Extinction %
Optical measurement. The value (100/Extinction Ratio).
Extinction dB
Optical measurement. The value (10*log10(Extinction Ratio)).
Mean dBm
Optical measurement. Average optical power (10*log10(Mean/0.001)).
With no menus displayed, the measurement readouts appear far right of the
display graticule. (See Figure 3–55.) You can display and continuously update as
many as four measurements at any one time. With any menu displayed, the
readouts move to the right side of the graticule area.
Measurement 1 is the top readout. Measurement 2 is below it, and so forth. Once
a measurement readout is displayed in the screen area, it stays in its position
even when you remove any measurement readouts above it.
Measurement Readouts