Black Box Industrial Serial to Multi-mode Fiber Optic Converter User Manual

Page of 5
MED100A-0908-1/5 
          p/n 
6132r3 
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018 
Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746 
To contact us about Black Box products or services: 
info@blackbox.com
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Specifications   
Serial Technology
 
RS-232 
TD, RD, GND 
RS-485 2-Wire 
Data A(-), Data B(+), GND 
RS-422/485 4-Wire 
TDA(-), TDB(+), RDA(-), RDB(+), GND 
Serial Connector 
Terminal Block (24 to 14 AWG) 
Data Rate  
 
RS-232  
Up to 115.2 Kbps 
RS-422/485 
Up to Up to 460.8 Kbps 
Isolation 
2KV RMS, 1 minute 
Industrial Bus 
MODBUS ASCII/RTU 
Fiber Optic Technology
 
Type / Wavelength 
Multi-mode / 820 nm  
Output Power 
(-) 17 to (-) 10 dBm 
Receive Sensitivity 
 (-) 25.4 dBm to (-) 24 dBm 
Cable  
62.5/125 micro-meter 
Connector 
ST 
Data Rate 
9.6 TO 115.2 kbps 
Maximum Distance 
2.5 miles (4 km) 
Idle State 
Transmitter Light ON 
Power 
Source  
External  
Input Voltage 
10 to 30 VDC 
Power Consumption 
4.2 Watts 
Connector 
Terminal Block (24 to 14 AWG) 
Mechanical 
LED Indicators 
Serial TD, RD, and Power 
Dimensions 
4.3 x 2.3 x .95 in (11 x 9 x 2.5 cm) 
Enclosure 
35mm DIN Mount, Plastic 
Weight 
0.4 lbs (182 g) 
Environmental 
Op Temperature 
- 40 to 176°F (- 40 to 80°C)  
Storage Temp 
- 40 to 185°F (- 40 to 85°C) 
Op Humidity 
0 to 95% Non-condensing 
Regulatory 
Approvals 
FCC, CE,  
MTBF 460854 
hours 
MTBF Calc. Method 
Parts Count Reliability Prediction  
 
MED100A 
Industrial Serial to Multi-mode Fiber Optic Converter 
9
 Data Rates up to 115.2 kbps 
9
 2.5 Mile (4 km) Range 
9
 10 to 30 VDC Input Voltage 
9
 Wide Operating Temperature 
9
 2000V Isolation  
9
 MODBUS ASCII/RTU Compatible 
9
 EMI/RFI Protection 
 
The MED100A is our Industrial Serial to Multi-mode Fiber 
Optic Converter. Designed for industry, it extends serial data 
range up to 2.5 miles and provides the most versatile 
connection possible between any asynchronous full or half-
duplex serial equipment. In addition to direct point-to-point 
connectivity, it is capable operating in a multi-drop mode. This 
allows one serial device to communicate with up to 31 others 
around a fiber optic ring. Since it supports mixed serial 
standards, you can replace other converters and isolators and 
add the EMI/RFI immunity inherent to fiber optic 
communications.   
 
In RS-232 mode, the MED100A supports transmit and 
receive data. Handshaking signals are not passed through.  
 
An Automatic Send Data Control circuit controls the RS-
422/485 driver chip, eliminating the requirement for special 
software.  
 
Easy to install and configure, it has an 8 position DIP 
Switch to set up the RS-422/485 parameters and terminal 
blocks to connect serial signals and power.