Zebra Technologies 2237A10L010 User Manual

Page of 230
143
Routine Maintenance
Replace the Fuse
9/6/07
Xi
IIIPlus/R110Xi/R170Xi User Guide
13383L-004 Rev. A
Replace the Fuse
The instructions that follow are for the 90XiIIIPlus, 96XiIIIPlus, 140XiIIIPlus, 170XiIIIPlus
R170Xi, and 220XiIIIPlus printers only. Fuses are not user-replaceable in the 110XiIIIPlus and 
R110Xi
The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry 
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is 
provided as a spare. The end caps of the fuse must bear the certification mark of a known 
international safety organization (see 
To replace a faulty fuse, complete these steps:
1.
Use a small-blade screwdriver or similar tool to remove the fuse holder. 
The fuse holder is part of the AC power entry module at the rear of the printer (
).
Figure 29 • AC Power Entry Module
2.
Remove the faulty fuse and install a new fuse in the in-circuit position (
Caution • 
Turn the AC power switch off (O) and remove the power cord before performing 
this procedure.
1
Power switch
2
Fuse holder
3
AC power entry module
4
Small-blade screwdriver
Important • 
 If you use the spare fuse, be sure to order a replacement fuse from an 
authorized Zebra distributor. The spare fuse should be the exact type and rating as the 
original in-circuit fuse.
1
2
3
4