Zebra Technologies 2237A10L010 User Manual

Page of 230
59
Operations
Adjust Media Sensors
9/6/07
Xi
IIIPlus/R110Xi/R170Xi User Guide
13383L-004 Rev. A
4.
Using the tip of the screwdriver, slide the upper sensor along the slot to the desired 
position (for non-continuous media with a notch or hole in the media, the sensor must be 
directly above the notch or hole).
5.
Tighten the adjustment screw to secure the upper media sensor.
Upper Media Sensor—Outside Half of Media
To adjust the upper media sensor for the outside half of the media, complete 
these steps (all models except the 220Xi
IIIPlus):
1.
Remove the ribbon (if ribbon is used).
2.
Locate the upper media sensor. The upper media sensor eye is directly 
below the adjustment screw head. 
3.
Using a Phillips-head screwdriver, remove the upper media sensor adjustment screw.
4.
Lift the upper media sensor assembly from the slot, and move it and the wire cover to the 
outside slot. Carefully pull the wires through the cable tie. You may need to set aside the 
sensor wire cover if the adjustment is too far to the outside.
5.
Replace and slightly tighten the adjustment screw.
6.
Slide the upper media sensor along the slot to the desired position (for non-continuous 
media with a notch or hole in the media, the sensor must be directly above the notch or 
hole).
7.
Tighten the adjustment screw.