Using ,m3 to Set the Truncate Flag  
Purpose  This is an argument for the c12 command that customizes the PDF417 bar code.
Syntax  This parameter, which defaults to 0, is the truncate flag. When set, the bar code will 
print without right row indicators and with a one-module wide stop character.
Supported  
Based on testing, this command works the same on the Zebra printer with 
APL-I firmware as on the 3400D printer.
Notes  
It enables you to enable printing the symbol in truncated form or to disable printing in 
truncated form.
Default: m3 = 0
Values for ,m3,
0
 = 
disables truncating
1
 = 
enables truncating
It is highly recommended that you use the default setting for 
,m3
 in order to reduce errors and 
maintain a better reading performance.
This shows the maximum allowable characters for the 3 character sets.
Important  Use these guidelines. Due to the fact that 2-dimensional symbols encode data by 
compressing it, the capacity varies due to the data being encoded.
Character Set
 Data Capacity
Full ASCII
1108
Alphanumeric
1850
Numeric
2725