Trendnet 1206 User Manual

Page of 24
I206 V.92 PCI MODEM USER’S MANUAL 
                                                                                                                           
Rev.1.00.2.1.57.75
 
- 20 - 
Section 3     
Troubleshooting 
 
Your modem is designed to provide reliable and trouble-free functionality, however, should you experience 
any difficulty, the information contained in this section will assist you in determining and resolving the source 
of the problem.   
 
Problem: Modem does not respond to AT commands 
Possible solutions:   
1. 
Make sure the modem is not configured with a conflicting COM port and IRQ setting. Make sure the 
 communication software is configured with the correct COM and IRQ settings (the same COM port
 and IRQ as the modem). Your communications software will not be able to send or receive any data if it 
is not configured to match the COM port and IRQ settings for the modem.   
 
DOS based communication program is not working with this modem neither can you operate the  
 
modem in MS-DOS prompt screen. 
   
2. 
Make sure the modem is properly initialized using the driver software. The software may improperly   
   
Initialize your modem because you have selected an incorrect modem type. You may also be prompted 
to enter an initialization string by the software. Use AT&F as your initialization string. 
 
Problem: Modem dials but does not connect 
Possible solutions: 
1. 
Be sure the IRQ setting is identical on the modem and the software. 
2. 
Make sure that the phone line is working properly. A noisy line will prevent proper modem operation.   
 
Problem: Modem makes a connection but no data appears on screen 
Possible solutions: 
3. 
Make sure all communication parameters (baud rate, data, stop, and parity bits) are properly configured 
and are identical on both sides. Be certain hardware flow control (RTS/CTS - default) is enabled in both 
the modem and the communication software. 
4. 
Press the ENTER key several times. The remote system may be waiting to receive your data before it 
begins. 
5. 
Make sure the correct terminal emulation mode is being used in the software (refer to software manual). 
 
Problem: Modem displays errors while on-line with a remote modem 
Possible solutions: 
6. 
Make sure Call Waiting is turned off. 
7. 
Make sure RTS/CTS hardware flow control is enabled (do not use XON/XOFF software flow control 
when transferring binary files). 
8. 
Make sure the data speed is not faster than your computer capability. Operating too many applications