Maxon Telecom MM-6280IND User Manual

Page of 70
 
Extended AT Commands Manual 
Page 66 of 70 
2009-06-25 
1 4 .  C E L L U L A R   E X T E N D E D   A T   C O M M A N D   S E T  
AT command lines containing the command set specified start with “AT” and end with a carriage 
return. Default configurations appear in boldface type. 
14.1.1.  Cellular AT parameter commands 
Table 14.85  AT parameter commands 
Command 
Description 
Packet 
Data 
STUIII 
+CDS 
Um Interface Data Compression. This extended-format 
compound parameter controls the V.42bis data 
compression function on the Um interface. The command 
format is the same as for the TIA/EIA/IS-131 +DS 
command. 
0,1,2048,6 (Default) 
Range: (0-0),(1-1),(512-65535),(6-250) 
N/A N/A 
+CBC? 
Battery Charge. 
Read-only. Returns <BCS>,<BCL> 
BCS: (S=source) 
0: Response to BCS will always be 0 since MT2 cannot 
discriminate between battery and other power supply 
sources. 
BCL: (L=level) 
n.n: Current source level in Volts 
O N/A 
+CRC=<value> 
Cellular Result Codes (see Table 4.4.2-1). 
0: Disable Cellular Result Codes 
1: Enable Cellular Result Codes 
N/A N/A 
+CFC=<value> 
Um Interface Fax Compression. 
0: No compression (Default) 
Range not supported: 
1: V.42bis compression with parameters  as  set  by  the 
+CDS command 
2: Modified Read compression 
N/A N/A