EMC P/N 300-002-803 User Manual

Page of 216
Limitations
157
Configuring a Boot Device on an EMC Storage Array
When attached to a Symmetrix, the physical-to-logical split must 
be such that you meet the minimum required disk space required 
to install the Linux operating system. Refer to your Linux 
distribution for these requirements.
For RHEL 4.5 boot from a LUN with VCM gatekeeper existing on 
a Symmetrix, you may receive an "unhandled exception with 
ZeroDivisionError" message when partitioning the boot LUN. 
Remove the VCM gatekeeper from the FA port and the 
installation will be successful.
VNX series- or CLARiiON-specific limitations
Consider the following VNX series- or CLARiiON-specific 
limitations:
Prior to the installation on a VNX series or CLARiiON LUN, the 
Linux host must have been manually registered on the array and 
assigned to a Storage Group. At least one LUN must be bound to 
the host's Storage Group and owned by the SP connected to the 
adapter being used for the fabric boot. The VNX series or 
CLARiiON storage system SP should be zoned to the 
lowest-numbered channel in the server and the lowest-numbered 
path to the boot LUN must be the active path.
EMC recommends, although it is not required, that the boot LUN 
be assigned Host LUN ID 0.
During the installation procedure, it is recommended, but not 
required, that only one LUN be assigned to the Storage Group for 
ease of use. Once the installation has completed, additional LUNs 
may be added to the Storage Group.
Booting from the SAN requires the use of a 
Unisphere/Navisphere Management station with the 
Unisphere/Navisphere Manager or NaviCLI. The stations must 
be separate from the boot server, but networked to the VNX series 
or CLARiiON storage system.