SERIES II INTELLIGENT DATA/FAX MODEMS
7.5  Remote Configuration/Callback Security 
S-Registers
The following S-Registers are used with Remote Configuration and
Callback Security features.
Remote Configuration Character (S13)
S13 defines the Series II Modem remote configuration escape character.
When the S13 character is entered three consecutive times from a
remotely connected site, your modem responds to it with its Remote
Configuration procedure.
Units:
Decimal equivalents of ASCII characters
Range:
0-127
Default:
37 (% sign)
Callback Time Delay (S15)
S15 defines the time delay for Callback attempts after initial passwords
have been exchanged between modems.
Unit:
Seconds
Range:
10-255
Default:
20
Callback Attempts (S16)
S16 defines the number of Callback attempts after initial passwords
have been exchanged between modems.
Unit:
Attempts
Range:
1-255
Default:
4