Black Box 3600 User Manual

Page of 270
Protocols
Modem 3600
6-3
Direct Mode
The DTE speed and DCE speed are forced to be the same. No error 
control or buffering.
Note
In direct mode, with the DCE link established at a rate other 
than the original DTE speed, the modem issues the connect 
message for the new DTE speed at the original rate. All 
subsequent data will be sent to the DTE at the new DCE 
speed.
Flow Control
If the serial port speed exceeds that of the modem connection, 
characters may be sent by the DTE to the modem faster than it can send 
them to the remote modem. The modem holds characters in an internal 
buffer until they can be transmitted. When this buffer is full, the modem 
uses flow control to cause the DTE to stop sending characters. As the 
modem continues to transmit data and the buffer empties, flow control is 
again used to cause the DTE to resume sending data. The modem can 
use hardware flow control (RTS/CTS) or in-band flow control (XON/
XOFF).
Protocol Commands
These commands enable or control the various data compression, flow 
control, and error correction options of the modem. Tabl e6-1 lists the 
features associated with each mode. 
Note
Bold text
 indicates command parameter defaults.