Test Mode Operation
Modem 3600
7-7
Remote Digital Loopback with Self Test   &T7
After making the data connection, enter the escape sequence to return to 
command mode. Entering &T7 places the remote modem in digital 
loopback provided the remote operator enters &T4 to allow an RL 
request. Once in RDL/TP, the local modem transmits a test pattern and 
automatically verifies that the remote modem is looping the pattern back 
(Figure 7-5). Enter &T to exit RDL/TP and return to command mode. 
Enter the O command to return online in data mode.
Exiting RDL/TP the modem responds with a three digit value between 0 
and 255 representing the number of errors which occurred during test 
pattern detection. If errors occur, repeat the test several times to verify 
the consistency of the problem, then use the analog loopback tests to 
isolate the problem.  
Figure 7-5.  Local Modem Initiating Remote Digital Loopback
with Test Pattern
Test Pattern   %T
In Test Pattern, transmitted data from the local DTE is blocked and 
replaced by a V.52 compatible test pattern. When the modem transmits 
the test pattern, it expects to receive the same pattern.
Bilateral Digital Test Enable / Disable   *DG
Enable or disable bilateral test functions. 
Command
 Operation
*DG
 Bilateral digital loop disabled 
*DG1
 Bilateral digital loop enabled