Security
Modem 3600
8-5
Operating without High Security
The modem is factory set with security disabled. In this mode the local 
DTE is connected to the local modem as usual, but the command to 
enable or view the status of the security feature will be accepted and 
processed. 
Operating with High Security
With high security enabled, each user must follow the appropriate logon 
procedure. The procedure for remote users is determined by their 
assigned security level. Upon termination of the connection, the secured 
modem waits for the next call and password sequence. A local user must 
logon to the secured Modem 3600 to use the unit.
If a power outage occurs, the logged -on user must logon again when the 
power is restored. For optimum security operation a reliable connection 
should be used. 
Security Levels
The Modem 3600 provides three levels of security to prevent 
unauthorized access by a remote user.
Level 1: Password Only
This is the lowest level of dial-up security. The user dialing in is 
prompted for an ID and password; if invalid, the modem hangs up.
Level 2: Password with Callback
This security level also accepts only calls from preset telephone 
numbers. After the user enters a correct ID and password, the modem 
looks up the telephone number and calls the user back at that number.
Level 3: Password with Callback and Password Re-
Entry
This is the highest level of security and is similar to Password with 
Callback except that after the user answers the callback call, the modem 
prompts again for the password.