Status Registers
Modem 3600
10-25
Callback Retry Delay   S76
The length of time that the modem waits, after an unsuccessful attempt 
to connect to the remote unit at the programmed callback number, 
before trying to place the call again. The default is 15 seconds. 
Lockout Threshold   S77
Set the number of incorrect remote user password attempts that can be 
made before the call is dropped. The default is 0. When remote 
configuration is active, the lockout occurs after seven attempts. 
Autocallback Timer   S78
The S78 register specifies the time in seconds that the modem waits 
before initiating autocallback. The default is 30 seconds.
Break Length   S79
The S79 register sets the length of the break sent to the DTE when a 
break signal is received. The range is from 1-255 in 20 ms increments. 
The default is 35 (700 ms).
Bit
Value
Command Description
7-0
0-255
--
Time in seconds (0 = disable)
Bit
Value
Command Description
7-0
0-255
--
Number of incorrect password attempts 
(0 = disable)
Bit
Value
Command Description
7-0
0-255
--
Time in seconds before autocallback
Bit
Value
Command Description
7-0
0-255
\B
\Bn
Send break