Hardware Options
Modem 3600
E-33
Factory Option Set # 6
(Asynchronous 4-wire Leased Line without V.42bis Protocol) 
(AT&F6)
MODEM OPTIONS
TEST OPTIONS 
DCE rate - 33600
Bilateral digital loop disabled
V.34 modulation *
DTE local test disabled
V.34 rate threshold low *
DTE remote test disabled
V.34 asymmetric rate enabled
Remote commanded test enabled
Normal originate
Test timeout off
Fast train disabled 
Auto retrain enabled 
DIAL LINE OPTIONS
SQ auto rate disabled
Tone dial
Transmit clock internal 
Auto dial #1
Leased line, 4-wire *
Wait for dial tone
Transmit level - 0 dBm *
Wait delay 2 seconds
Dial backup manual *
Pause delay 2 seconds
Lookback timer - 15 min *
Call timeout 30 seconds
Jack type RJ11 
Answer on 1 ring
Line current disconnect long
Autocallback disabled
Long space disconnect enabled 
V.22 guard tone disabled
DTE OPTIONS
Async data
PROTOCOL OPTIONS
DTE rate - 115200
LAPM protocol disabled *
8 bit, no parity
MNP protocol disabled *
AT command set enabled
Normal buffer mode
Ignores DTR *
Constant DTE speed
DSR forced high
DTE flow control disabled *
DCD normal
DCE flow control disabled *
CTS forced high
XON/XOFF pass through disabled DTE fallback disabled
Inactivity timer off
Options retained at disconnect
Break control 0 *
V.42 fast detect disabled *
SPEAKER OPTIONS
Volume low
On until carrier detect
*