American Dynamics ADCC0200 User Manual

Page of 56
39
Keyboard Installation and Operation
Appendix B: Monitor Arming Commands
Monitors are armed for alarm call up with codes that specify the following three parameters:
1.
The 
display method (single, dual, or block monitors).
2.
The 
queuing method (sequence or hold).
3.
The 
clearance method (instant, auto, or manual).
To arm a monitor with an ADCC0300 keyboard:
1.
Call the monitor to be armed.
2.
Enter the monitor arming code number (see table).
3.
Press the FUNCTION (
) key, press the F1 (
) key.
A keyboard operator can also program any monitor armed for instant or auto clearance, for clearance via manual
override. Manual override is enabled or disabled after the arming code is programmed. If enabled, an "A" will appear
after the three-letter acronym for the arming code that appears on the monitor status line.
When using the AD1024 matrix switcher/controller system, monitors can be armed through S3 system setup software
with a PC interface, or through the AD1024 embedded software with an ADCC0300 keyboard. Following is a table of
monitor arming codes and the commands that enable the codes.
* In dual display applications, the first three-letter acronym is displayed on the 
hold monitor. The second three-letter
acronym is displayed on the 
sequence monitor.
Monitor Arming Code
Monitor Acronym
Command Sequence
Display Arming Status
see entries below
300, FUNCTION, F1
Single, Sequence, Instant
SSI
301, FUNCTION, F1
Single, Sequence, Auto
SSA
302, FUNCTION, F1
Single, Sequence, Manual
SSM
303, FUNCTION, F1
Single, Hold, Instant
SHI
304, FUNCTION, F1
Single, Hold, Auto
SHA
305, FUNCTION, F1
Single, Hold, Manual
SHM
306, FUNCTION, F1
Block, Sequence, Instant
BSI
307, FUNCTION, F1
Block, Sequence, Auto
BSA
308, FUNCTION, F1
Block, Sequence, Manual
BSM
309, FUNCTION, F1
Block, Hold, Instant
BHI
310, FUNCTION, F1
Block, Hold, Auto
BHA
311, FUNCTION, F1
Block, Hold, Manual
BHM
312, FUNCTION, F1
Dual, Hold, Instant
DHI/DSI*
313, FUNCTION, F1
Dual, Sequence, Instant
Dual, Hold, Auto
DHA/DSA*
314, FUNCTION, F1
Dual, Sequence, Auto
Dual, Hold, Manual
DHM/DSM*
315, FUNCTION, F1
Dual, Sequence, Manual
Disarm Monitor
316, FUNCTION, F1
Enable Monitor Override
317, FUNCTION, F1
Disable Monitor Override
318, FUNCTION, F1