SEAL 44Ultra Laminator User Manual

Page of 49
 
 
Disassembly / Reassembly Procedures 
21 
 
4-4  Control System Board & Software 
 
4-4-1  Control System Board 
 
To change the Control System Board, it is necessary to disassemble Rear Panel, as described in 
section 4-3. 
 
1.  Remove all connectors. 
 
2.  Remove the five M3 socket screws. 
 
3. Remove 
the 
print. 
 
Assemble in reverse order. 
 
Never change the settings of the three potmeters, marked 1, 2 and 3 in figure 15. 
 
 
 
4-4-2 Software 
 
The Control System of the Seal 44 Ultra is software driven. 
The software resides in a small embedded controller, mounted on the Control System Board. 
Necessay tools: IC extractor 
Approximate time: 1 minute 
 
To change / upgrade the software, it is necessary to perform the ‘Rear Panel’ Procedure, described in 
section 4-3. 
 
Make sure that the power cord is disconnected from the mains ! 
 
 
1.  See figure 15. Arrow #4 points to the processor (it usually has a sticker showing the software 
version). Carefully remove it using the IC extractor. 
2.  To insert the new processor, make sure that its pins are not bent, and that the small notch on the 
side of the processor matches the symbol, printed on the PCB (arrow #4 actually points to the 
notch). Use the extractor to insert the new processor. 
3.  Discard the old processor. 
 
fig. 15 
1 2  3