4.25  Fluorescent Lamp 
4  Replacement Procedure 
TECRA M1 Maintenance Manual (960-436) 
 
4-85 
 
4.25  Fluorescent Lamp 
This system uses LCD modules from the following suppliers. The procedure for replacing the 
fluorescent lamp is different for each LCD module. Refer to the appropriate procedure. 
Type 
Part No. 
Supplier 
Section 
14.1-inch (XGA) 
VF2092P03 
TOSHIBA 
4.25.1 
14.1-inch (SXGA+) 
VF2074P01 
Sharp 
4.25.2 
 
NOTE:  - When working with an LCD module, always use a flat, grounded table. 
 
- Handle the backlight unit in the environment without dust, such as on the clean 
bench.  Keep the worktable free from  any screws or other material that may 
scratch the LCD surface. 
 
- Use an anti-static or protective sheet. 
 
- When replacing the FL unit, cover with a finger protector or similar to prevent 
soiling or scratching the LCD panel. 
 
- Be careful when handling the lamp. Excessive force may break the lamp. 
 
- Be careful not to soil or deform the lamp reflector. 
 
- Make sure that the power of the LCD module is turned off before connecting 
or disconnecting cables and connectors.