StarTech.com CABCONS1716I User Manual

Page of 65
Instruction Manual
50
Connecting Serial Remote Control Modules to the CABCONS1716I
The cable for each serial device is similar to a phone cable and uses an RJ-14 connector. 
For the first module, connect the cable (provided) to the R-Port on the rear panel of 
the CABCONS1716I. Connect the opposite end to the DATA OUT (or similar) port on 
the Serial Remote Control unit. Note that some devices may use an integrated cable, 
so you will not need to make a separate connection on the serial device. Once you 
have added the first serial device to the CABCONS1716I, you can connect additional 
modules to the DATA IN (or similar) port on the previous module in the chain. 
Once the cabling is attached, the module becomes active after a 15 second 
initialization period. For specific information regarding cabling and status indicators for 
a specific serial console, refer to the instructions that came with the product.
Configuring/Viewing Serial Remote Control Modules through the  
Web Interface
Once you have one or more R-Port serial devices connected, you will be able to 
configure and manage them through the Web interface. You may need to modify the 
default settings on CABCONS1716I to match your various R-Port modules’  
default configuration.
Consult the documentation that came with your R-Port module to determine if 
you need to modify the default settings to complete the installation. To be able to 
configure your RPort modules, you must be logged in as admin. Other users will be 
able to view which modules are active, but cannot configure them.
Once you are logged in, choose the Admin/Setup option from the menu at the top of 
the Home screen in the Web interface. Click External Serial consoles setup and control.
You will be presented with the Serial Consoles Attached menu, and a table with 
the following headings:
#:
You can assign a value (1 ~ 99) to each attached serial remote control module. This 
does not affect the configuration or operation of the device in any way, but is simply a 
means to sort this list for ease of management.
Name/Description: An identifier for the R-Port module. Like the number assignment, 
it is for ease of administration only.
Baud (bps): This is the communication speed for the device, and the setting here 
must match the setting on the module itself. All common baud rates between 300 and 
115,200bps are supported.
Mode: Sets the character framing scheme that the CABCONS1716I will use with the 
R-Port module. You can choose from the following selections: