AMX NXC-VAI4 Leaflet

Page of 2
Installation Guide
NXC-VAI4 
Voltage Output/Analog Input Card
NetLinx Control Cards and NetModules
NetLinx Control Cards can be installed in either the NXF CardFrame, NI-4000, or 
NetModules. This document provides basic specifications and wiring information for 
the NetLinx Control cards. For detailed information on the cards, refer to the NetLinx 
CardFrame, Control Cards, and NetModules 
Instruction Manual available on-line via 
www.amx.com.
NXC-VAI4 Analog Voltage Control Card
The NXC-VAI4 Analog Voltage Control Card (FG2025) provides 4 independent 
analog-to-digital inputs and four independent digital-to-analog outputs, which are 
controllable over the ICSP network. Each port can be configured for a variety of DC 
input and output signals. The NXC-VAI4 incorporates the functionality of the AXC-VAI2 
and AXC-VRG AXlink cards.
Pinouts and Functions:      
Channel Assignments:
Off = 50% voltage, and all channel assignments are mutually exclusive. 
Note: PUPN and PX must be set for all eight levels before using the card.  
NXC-VAI4 Specifications
Power Requirements:
330 mA @ 12 VDC
Inputs:
Four high-impedance analog DC inputs.
Outputs:
Four analog DC outputs (user-configurable).
D/A, A/D conversion:
0-bit A/D and D/A converters for analog sampling and 
control.
Available input voltages:
0 V to +12 V.
Available output voltages:
-12 V to +12 V:
The output voltage may be software-configured for any min 
and max levels between -12 and +12 VDC.
• Maximum output current = 60 mA per output.
• Over-voltage protection to +28 VDC.
External reference:
A user supplied external reference voltage can be used to 
set the maximum voltage range for the D/A outputs. The full 
analog output range is scaled to fit the maximum range set 
by the external reference.
Output voltage may be set to any level between 0-12 VDC, 
referenced to the external reference voltage input and the 
NXC-VAI4 power supply GND.
External reference input: 
(EREF, 1 for each output)
Maximum external reference input voltage = +12VDC.
Over-voltage protection to +28 VDC.
Internal reference output: 
(IREF)
+5 V reference output, maximum current = 60 mA.
This output is intended to drive a ground-referenced load.
I/O Status LEDs 1-8: 
(two LEDs per channel)
LEDs light to indicate ON status.
4 yellow LED's (one per channel) light to indicate input signal 
changes reported to the Master.
4 red LED's (one per channel) light to indicate output signal 
changes. Output LEDs blink to indicate that the power-up or 
limit levels have not been set.
• LED 1: Output #1 (red)
• LED 2: Input #1 (yellow)
• LED 3: Output #2 (red)
• LED 4: Input #2 (yellow)
• LED 5: Output #3 (red)
• LED 6: Input #3 (yellow)
• LED 7: Output #4 (red)
• LED 8: Input #4 (yellow)
Wiring:
Captive-wire connectors.
Device ID: 
0x010D
Firmware ID: 
• 0x0113 (Download) 
• 0x0114 (Boot)
NXC-VAI4 Pinouts, Signals, and Functions
Pin Function
Pin Function
Pin Function
1
Output #1  (GND)
9
Input #1  (GND)
17
+5 V Reference output (GND)
2
Output #1
10
Input #1
18
+5 V Reference output
3
Output #2  (GND)
11
Input #2  (GND)
19
External Reference input (GND)
4
Output #2
12
Input #2
20
External Reference input 
5
Output #3  (GND)
13
Input #3  (GND)
6
Output #3 
14
Input #3
7
Output #4  (GND)
15
Input #4  (GND)
8
Output #4
16
Input #4
NXC-VAI4 Channel Assignments
Channel
State Function
Channel 1
ON
While channel 1 is ON, the voltage on Output 1 will ramp up at the 
"CURRENT OUTPUT 1 RAMP UP TIME" rate. The voltage ramp 
stops if the maximum is reached.
OFF
Stops voltage ramping on Output 1 at current value.
Channel 2
ON
While channel 2 is ON the voltage on Output 2 will ramp up at the 
"CURRENT OUTPUT 2 RAMP UP TIME" rate. The voltage ramp 
stops if the maximum is reached.
OFF
Stops voltage ramping on Output 2 at current value.
Channel 3
ON
While channel 3 is ON the voltage on Output 3 will ramp up at the 
"CURRENT OUTPUT 3 RAMP UP TIME" rate. The voltage ramp 
stops if the maximum is reached.
OFF
Stops voltage ramping on Output 3 at current value.
Channel 4
ON
While channel 4 is ON the voltage on Output 4 will ramp up at the 
"CURRENT OUTPUT 4 RAMP UP TIME" rate. The voltage ramp 
stops if the maximum is reached.
OFF
Stops voltage ramping on Output 4 at current value.
Channel 5
ON
While channel 5 is ON the voltage on Output 1 will ramp down at the 
"CURRENT OUTPUT 1 RAMP DOWN TIME" rate. The voltage 
ramp stops if the minimum is reached.
OFF
Stops voltage ramping on Output 1 at current value.
Channel 6
ON
While channel 6 is ON the voltage on Output 2 will ramp down at the 
"CURRENT OUTPUT 2 RAMP DOWN TIME" rate. The voltage 
ramp stops if the minimum is reached.
OFF
Stops voltage ramping on Output 2 at current value.
Channel 7
ON
While channel 7 is ON the voltage on Output 3 will ramp down at the 
"CURRENT OUTPUT 3 RAMP DOWN TIME" rate. The voltage 
ramp stops if the minimum is reached.
OFF
Stops voltage ramping on Output 3 at current value.
Channel 8
ON
While channel 8 is ON the voltage on Output 4 will ramp down at the 
"CURRENT OUTPUT 4 RAMP DOWN TIME" rate. The voltage 
ramp stops if the minimum is reached.
OFF
Stops voltage ramping on Output 4 at current value.
Channel 9
ON
Reserved [do not use].
OFF
Reserved [do not use].
Channel 10
ON
While channel 10 is ON the voltage on Output 1 is set to 100%.
OFF
Sets Output 1 voltage to 50%.
Channel 11
ON
While channel 11 is ON, the voltage on Output 2 is set to 100%.
OFF
Sets Output 2 voltage to 50%.
Channel 12
ON
While channel 12 is ON, the voltage on Output 3 is set to 100%.
OFF
Sets Output 3 voltage to 50%.
Channel 13
ON
While channel 13 is ON, the voltage on Output 4 is set to 100%.
OFF
Sets Output 4 voltage to 50%.
Channel 14
ON
While channel 14 is ON, the voltage on Output 1 is set to 0%.
OFF
Sets Output 1 voltage to 50%.
Channel 15
ON
While channel 15 is ON, the voltage on Output 2 is set to 0%.
OFF
Sets Output 2 voltage to 50%.
Channel 16
ON
While channel 16 is ON, the voltage on Output 3 is set to 0%.
OFF
Sets Output 3 voltage to 50%.
Channel 17
ON
While channel 17 is ON, the voltage on Output 4 is set to 0%.
OFF
Sets Output 4 voltage to 50%.
Channel 18
ON
While channel 18 is ON, the voltage on Output 1 is set to 75%.
OFF
Sets Output 1 voltage to 50%.
Channel 19
ON
While channel 19 is ON, the voltage on Output 2 is set to 75%.
OFF
Sets Output 2 voltage to 50%.
Channel 20
ON
While channel 20 is ON, the voltage on Output 3 is set to 75%.
OFF
Sets Output 3 voltage to 50%.
Channel 21
ON
While channel 21 is ON, the voltage on Output 4 is set to 75%.
OFF
Sets Output 4 voltage to 50%.
Channel 22
ON
While channel 22 is ON, the voltage on Output 1 is set to 25%.
OFF
Sets Output 1 voltage to 50%.
Channel 23
ON
While channel 23 is ON, the voltage on Output 2 is set to 25%
OFF
Sets Output 2 voltage to 50%.
Channel 24
ON
While channel 24 is ON, the voltage on Output 3 is set to 25%
OFF
Sets Output 3 voltage to 50%.
Channel 25
ON
While channel 25 is ON, the voltage on Output 4 is set to 25%
OFF