Mio Modero DMS Conduit Box
Overview
For more detailed installation, configuration, programming, and operating 
instructions, refer to the Mio Modero DMS & Mio Modero DMS Pinnacle 
instruction manual available on-line at www.amx.com.  
Installation
It is recommended that you cutout the surface slightly smaller than what is 
outlined in the installation drawings so that you can make any necessary cutout 
adjustments.
Before you begin, if you are using the 2-pin power connector, verify that the 
terminal end of the power cable is not connected to a power source.
Note:  The device and conduit box must have an Earth ground.
If assembled, pull the Mio Modero DMS from the conduit box.
Rough-in Installation of the Conduit Box
1.
Remove the tabs for the expansion clip installation from the conduit box by 
bending back and forth with pliers. See FIG. 1.
2.
Use screws through the rough-in tabs to the stud. The conduit box is 3.5" 
(8.89 cm) deep. The front of the conduit box should be flush with the front 
surface of the sheetrock. While the conduit box can be recessed it should 
never stand proud to the surface.
3.
Run 12V or CAT5/6 cable and an Earth ground wire into the conduit box. 
Locations to run power wiring into the conduit box are shown in FIG. 1. 
4.
Insert the cardboard paint shield into the conduit box if the Mio Modero 
DMS will not be installed at this time.
Expansion Clip Installation of the Conduit Box
The expansion clip installation method can be used for podium or other flat 
surface installations.
1.
Cut out the surface for the Mio Modero DMS conduit box using the 
dimensions shown in FIG. 2. A template is included to help you determine 
dimensions.    
2.
Remove the tabs for the rough-in installation from the conduit box by 
bending back and forth with pliers. See FIG. 1.
3.
Thread the CAT5/CAT6, the Earth ground wire and, if necessary, the power 
cables through one of the provided breakaway access points on the 
conduit box. Leave enough slack in the wiring to accommodate any 
re-positioning of the unit.
4.
Thread the 2 drywall screws through the 2 locations center on both top and 
bottom of the conduit box (FIG. 1) and then through the expansion clips. 
5.
Insert the conduit box and expansion clips into the cutout until the rim of the 
conduit box is flush against the wall.
6.
Tighten the 2 drywall clip sets (screws and clips) until the conduit box is 
flush against the wall.
7.
Insert the provided cardboard paint shield into the conduit box if the Mio 
Modero DMS will not be installed at this time.
Installing the Conduit Box without the Use of Tabs
A brick and mortar installation environment is a great example where no tabs are 
required.
1.
Remove both the tabs for the rough-in installation and expansion clip 
installation from the conduit box by bending back and forth with pliers. See 
FIG. 1.
2.
Thread the CAT5/CAT6, the Earth ground wire and, if necessary, the power 
cables through one of the provided breakaway access points on the 
conduit box. Leave enough slack in the wiring to accommodate any 
re-positioning of the unit.
3.
Insert the provided cardboard paint shield into the conduit box.
4.
While conducting this installation, confirm nothing gets into the conduit box, 
i.e., mortar.
Mio Modero DMS Conduit Box (FG039-11) Specifications
Dimensions (HWD)
6.25 (158.8 mm) x 3.08 (78.3 mm) x 3.50 (88.9 mm)
Weight
• Conduit box - .85 lbs (.39 kg)
• Magnetic Post Housing - .10 lbs (.05 kg) (MA2408-01)
Included 
Accessories:
• 4 screws, #2-56 X .250 (800105)
• 1 ground screw, #8-32 X 3/8 wafer head, green (80-0149)
• Mounting template (68-2408-01)
Other AMX 
Equipment:
• Mio Modero DMS (FG2408-01xx)
• Mio Modero DMS Pinnacle (FG2408-02xx
xx indicates color
FIG. 1  
Mio Modero DMS Conduit Box
Expansion clip
installation tabs
Rough-in
installation tabs
Keyhole CAT5/6
and 12V access
Earth
ground
point
FIG. 2  
Mio Modero DMS Cutout Installation Dimensions
Notches are only
required for 
expansion clip
installations