B&B Electronics 232PCC2 User Manual

Page of 24
 
Documentation Number 232PCC23799 Manual 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial  Park – Oranmore, Galway, Ireland – Ph +353-91-792444 – Fax +353-91-792445 
 
 
  Reboot the system and note the message displayed when 
the 232PCC2 Client Driver is loaded.  If the Client Driver 
reports an "invalid command line option", correct the entry 
in the CONFIG.SYS file and reboot the system again.  If 
the Client Driver reports "Card and Socket Services not 
found", a version of Card and Socket Services must be 
installed on the system or the 232PCC2 Enabler program 
must be used to configure the adapter.  If the Client Driver 
reports the desired adapter configuration, the installation 
process is complete and the 232PCC2 may be removed 
and / or inserted from the system as desired.  On each 
insertion into the PCMCIA socket, the 232PCC2 will be 
automatically re-configured according to the command 
line options. 
Command Line Options 
 
The 232PCC2 Client Driver accepts up to eight command line 
arguments from the user to determine the configuration of the 
232PCC2.  If any arguments are provided, the Client Driver will 
attempt to configure any 232PCC2s with the options specified in the 
order they are entered on the command line.  Each argument must 
be enclosed in parenthesis and must be separated from other 
arguments by a space on the command line.  Within each argument, 
any or all of the following parameters may be specified using a 
comma (no spaces) to separate each parameter: 
 
Baddress 
specifies the base I/O address of the 232PCC2 in 
hexadecimal and must reside on an even 16-byte 
(10H) boundary.  This option must be omitted if using 
the Dmode option.  If both the Dmode and Baddress 
option are omitted, Card and Socket Services will 
assign a block mode base address. 
 
Dmode 
specifies a COM mode base I/O address configuration 
for the 232PCC2.  The D1 option configures the 
232PCC2at COM1/COM3 (3F8/3E8), and the D2 
option configures the 232PCC2 at COM2/COM4 
(2F8/2E8).  This option must be omitted if using the 
Baddress option.  If both the Dmode and Baddress 
options are omitted, Card and Socket Services will 
assign a block mode base address.