Emergency recovery
Problem:
You have a unit already configured and,
- you do know your password, but
- have lost, misconfigured or don't know the IP address of the unit, and
- you cannot obtain a login on any port (including the console port)
The emergency recovery method is to use BOOTP (see 
). 
•Setup a host machine on your network to run BOOTP. Using the ethernet 
address of the unit (printed on the base of the product) BOOTP will assign 
the unit a known IP address. 
•Now, you should be able to telnet into the unit and change its IP address. 
Using BOOTP to recover access to your unit in this manner will preserve all 
configuration settings - apart from the IP address.
Problems with framed Routing
Problem:
My SLIP/PPP link is running but I am not seeing any routing 
information propagated to my dial up clients.
Check:
Make sure that SLIP/PPP links are configured for route broadcasts, 
see section 9.1.
Wait for 30 seconds before checking again for new routes, routes are 
broadcast every 30 seconds.
Problem:
I can talk to my dial-up clients, but not any other machine on the 
network it is attached to.
Check:
Make sure that your dial-up client is configured to pass on RIP ( 
routing ) packets to it's other network interfaces. This may involve 
installing additional routing software on some operating systems.
Problem:
I have configured framed routing for a SLIP/PPP link but routing does 
not work.
Check:
Both  Remote IP Address and  Local IP Address need to be configured 