Conettix C900V2 | Installation Guide | 6.0   UL Standard 1610 and ULC S304 Intrusion System Installations 
 
Bosch Security Systems, Inc. | 8/08 | F01U087780-01 
21
 
 
Table 10:  Connection Sequence – C900V2 and Generic Control Panel in Separate Enclosures 
(UL Standard 1610, with or without Telephone Line) 
 
Seq
 
C900V2 Connection 
 
Control Panel Connection 
 
Other Connection 
RJ-45 PANEL connector  
to 
RJ-45 connector (telco dialer) 
 
 
2 RJ-45 
ETHERNET 
connector 
to 
 
 
LAN or WAN 
– V terminal 
to 
–12 to –24 VDC (common) 
 
 
V + 
to 
+12 to +24 VDC output 
 
 
Install an EOL resistor for 
the control panel across 
OUT2-L and OUT1-R 
 
 
 
 
OUT2-L TO OUT1-L 
 
 
 
 
OUT2-R TO OUT1-R 
 
 
 
 
OUT1-R 
to 
 
 
C900V2 enclosure closed-circuit 
tamper switch  
 
 
 
 
C900V2 enclosure closed-circuit 
tamper switch to control panel 
enclosure closed-circuit tamper 
switch 
10 
 
 
24-hour zone input common 
to 
Control panel enclosure closed-
circuit tamper switch 
11 
OUT2-L 
to 
24-hour zone input 
 
 
12 
 
 
Battery negative input 
to 
Battery negative terminal 
13 
 
 
Battery positive input 
to 
Battery positive terminal 
14 
 
 
AC input 
 
AC transformer 
15 
 
 
AC input 
 
AC transformer 
NOTE: The sequence numbers appear in the diagram in Figure 12.  
 
 
The optional telephone line is for programming and diagnostics only.