Bosch C900V2 User Manual

Page of 28
Conettix C900V2 | Installation Guide | Contents 
 
Bosch Security Systems, Inc. | 8/08 | F01U087780-01
 
2.2 Wiring 
 
Figure 5:  Wiring to a DS7400Xi in the Same Enclosure 
3
1
7
5
4
10
8
2
9
6
 
1 –  C900V2 
2 –  To LAN or WAN port 
3 –  DS7400Xi Control Panel 
4 –  Non-power limited area  
NOTE: All power limited wiring must be at least 
6.4 mm (0.25 in.) from the battery wiring. 
5 –  Battery 
6 –  EOL resistor for the control panel, attached to 
terminals 
7 –  DS7481 Single Phone Line Monitor (optional) 
8 –  Telco jack 
9 –  RJ31X 
10 – House telephone 
 
 
 
You can use the C900V2 with a variety of control 
panels. The next sections provide information for 
wiring the C900V2 to a generic control panel. Refer 
to Figure 5
 
 
The control panel’s phone line monitor 
becomes inactive when the C900V2 
intercepts the phone line between the 
telco service and the control panel. If 
phone line monitoring is required, use an 
external phone line monitor, such as the 
Bosch Security Systems, Inc. DS7481. 
The loss of a network connection closes 
the Output 2 relay contact on the 
C900V2. You can connect this output to 
a 24-hour zone on the control panel. 
 
 
 
The DS7400Xi is the only control panel 
approved by UL to be wired in the same 
enclosure as the C900V2. You must 
install any other control panel in a 
separate enclosure to receive the UL 
approval.