Avocent CCM User Manual

Page of 136
  Appendices        95
Appendix B: Device Cabling
Each CCM appliance serial port has an RJ-45 connector for attaching a serial device. Table B.1 
lists the pin assignments.
Modular adaptors are available to convert RJ-45 modular jacks to standard pinout configurations. 
Adaptors are available for use with:
CAT 5 cable (and CAT 6 cable for CCM4850 appliances).
Serial reversing cable. Reversing adaptors and cables are recommended for distances greater 
than 100 feet.
Adaptors for use with CAT 5 and CAT 6 cable
Table B.2 lists the adaptors available for use with CAT 5 and CAT 6 cable.
Table B.1: Port Pin Assignments
Pin Number
RS-232 Signal
Direction
Description
1
RTS
Output
Request to Send
2
DSR
Input
Data Set Ready
3
DCD
Input
Data Carrier Detect
4
RD
Input
Receive Data
5
TD
Output
Transmit Data
6
GND
(N/A)
Signal Ground
7
DTR
Output
Data Terminal Ready
8
CTS
Input
Clear to Send
NOTE: RI (Ring Indicate) is not supported
Table B.2: Adaptors for Use with CAT 5 and CAT 6 Cable
Part Number
Description
210122
RJ-45 to DB-9M (DTE) Adaptor
210120
RJ-45 to DB-9F (DCE) Adaptor
210124
RJ-45 to DB-25M (DTE) Adaptor
210123
RJ-45 to DB-25M (DCE) Adaptor
210125
RJ-45 to DB-25F (DTE) Adaptor
210121
RJ-45 to DB-25F (DCE) Adaptor