Samsung SNS-100/400 User Manual

Page of 38
SNS-100/400 Network Server 
 
12 
Ch3. Installation and Setting 
3.1. Power Input 
„  DC Power   
Only DC12V power may be supplied to this product. 
When using an adapter different from the one supplied by us (DC12V/4A), make sure that it is DC12V/2A or higher.   
„  DC Only 
 
For SNS-400, the recommended adapter specs are DC12V/2A, therefore, only use standard adapters.   
Chart 3-1 When the copper wire’s resistance is [20℃(68℉)] 
Copper Wire Size (AWG) 
#24(0.22
#22(0.33
#20(0.52
#18(0.83
Resistance (Ω/m) 
0.078 0.050 0.030 0.018 
DROP Voltage(V/m) 
0.028 0.018 0.011  0.06 
y  As seen in Chart 3-1, a voltage drop occurs and thus, in the case that the adapter output wire’s length is excessively connected 
to the network, a problem can occur with the network server.   
※  Server Operation Voltage: DC 12V±10% 
※  Depending on the type and manufacturer of the voltage load wire described in the above chart, there may be a deviation. 
 
3.2. Connecting to Monitor 
Connect the video output terminal on the back of the product to the monitor input terminal. 
 
                                                                        SNS-100 Network Server                                          Monitor 
y  Connection methods may differ depending on the used monitor and peripheral devices, so please refer to the users’ manual. 
y  Always connect after turning the device’s power off.