Paradyne 1900 User Manual

Page of 160
Appendix A. Installation Requirements
A-108
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
The bay must be installed and secured in accordance with standard 
telecommunications industry practices 
Use an Isolation Kit to isolate the bay from building structures and 
outside elements for "in-building" installations (i.e., enterprise, 
MDU, and MTU).
The bay must be electrically grounded according to standard 
telecommunications industry practices
BS1900 System Specifications
Table A-1, "BitStorm 1900 System Specifications" shows the power 
specifications for the BitStorm 1900 shelf.
 
Table A-1:   BitStorm 1900 System Specifications 
BitStorm 1900 System Specifications
Description
Front Mount 
10306
 
Full
1
Front Mount 
10224 Full
2
Lines Per Chassis
60 Lines, 10 Megabit
240 Lines, 10 Megabit
Weight
50 lbs.
46 lbs.
Height
12.1875”
12.1875”
Width
12”
12”
Required Rack Units
13
13
Depth
12”
12”
Cabled Depth
17.5”
17.5”
Cabled Ear to Front (Front Mount)
4”
4”
Cabled Ear to Front (Mid Mount)
7.75”
7.75”
Cabled Ear to Back (Mid Mount)
13.5”
13.5”
Cabled Ear to Back (Mid Mount)
9.75”
9.75”
Humidity (Non-Condensing)
1% to 90%
1% to 90%
Ambient Temp. Rating
5
o
C to 40
o
C
5
o
C to 40
o
C
Altitude
-200 to 13,123’
-200 to 13,123’