Appendix A. Installation Requirements
A-112
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
Installation Tools and Materials
The tools and materials required to install the BitStorm 1900 shelf 
include the following:
4 bay mounting screws 
1 medium Phillips-head screwdriver 
1 cross-connect block matching the existing blocks used in the 
facility MDF, such as Siemon R66, BIX, or AT&T 110 cross-
connect blocks
1 wiring punch-down tool intended for use with the cross-connect 
block
Cross-connect jumper wires (24 AWG, quantity varies) for tip/ring 
connections
01-30036-01
Filter Card, 3RU
12 filters; 
1 filter card per two 10306 cards
2 filter cards per 10224
04-00007-10
Champ to Dual Omni 
Grid
2 per four 10306 cards
2 per 10224
04-00008-18
Omni Grid to Dual Omni 
Grid
2 per 10224 w/filter shelf
04-00028-01
Omni Grid to Dual Omni 
Grid
1 per two 10306 cards with filter shelf
03-00003-01 
Air Baffle
1 per BitStorm 1900
01-00085-01
Bulk Pack 5 Fan Tray 
Filters
Replace every 6 months
(Required DC fan tray for NEBs 
compliance)
DO NOT install a filter in an AC fan tray 
– only the filter frame.
01-00084-01 
DC Fan Tray
1 per BitStorm 1900 w/MIU
(An air filter must be installed to meet 
NEBs)
01-00084-02
AC Fan Tray
1 per BitStorm 1900 w/MIU
(DO NOT install an air filter – only the 
air filter frame.)
Table A-2:   BitStorm 1900 Components (continued)
Part#
BitStorm Component
Rules/Capacity