Paradyne 1900 User Manual

Page of 160
1. BitStorm 1900 IP DSLAM 
1900-A2-GN20-00
BitStorm 1900 Installation and Maintenance Guide
1-31
BitStorm 1900 Component Requirements
Table 1-7, “BitStorm 1900 Component Requirements,”  provides the 
basic requirements for each component within the shelf.    
Table 1-7:   BitStorm 1900 Component Requirements
Part 
Number
Shelf 
Components
10306 
CO 
Modem 
Card
10224 
CO 
Modem 
Card
Special 
Instructions
01-00080-01
260 W DC 
power
Yes
Yes
Must use fan tray*
*Air filter is 
required for NEBs 
compliance
01-00079-01
260 W AC 
power
Yes 
Yes
Must use fan tray 
without an air 
filter
01-00075-01
MIU
Yes Yes
01-00084-01
Fan Tray, DC
Yes 
Yes
01-00084-02
Fan Tray, AC
Yes 
Yes
!
WARNING:   POSSIBLE EQUIPMENT DAMAGE!  To 
comply with Telcordia GR-1089-CORE, 
Outside Plant Voltage/Current Limiting 
Protection is required for each Outside Plant 
Exposed line.
!
WARNING:   POSSIBLE EQUIPMENT DAMAGE!  AC Fan 
Trays are shipped with an air filter frame. To 
ensure proper airflow, the frame must be 
installed. DO NOT install an air filter for the 
AC Fan Tray, only the frame.