Schottky Barrier Diodes (SBD)
MA2J704 
(MA10704)
Silicon epitaxial planar type
For super high speed switching
■ Features
• Forward current (Average) I
F(AV)
 
= 200 mA rectification is possible
• Small reverse current I
R
 (About 1/10 of I
R
 of the ordinary
products)
■ Absolute Maximum Ratings  T
a
 
= 25°C
Parameter
Symbol
Rating
Unit
Reverse voltage
V
R
20
V
Repetitive peak reverse voltage
V
RRM
20
V
Peak forward current
I
FM
300
mA
Forward current (Average)
I
F(AV)
200
mA
Non-repetitive peak forward
I
FSM
1
A
surge current 
*
Junction temperature
T
j
125
°C
Storage temperature
T
stg
−55 to +125
°C
Marking Symbol: 2S
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Forward voltage
V
F
I
F
 
= 200 mA
0.55
V
Reverse current
I
R1
V
R
 
= 10 V
2
µA
I
R2
V
R
 
= 20 V
5
Terminal capacitance
C
t
V
R
 
= 0 V, f = 1 MHz
30
pF
Reverse recovery time 
*
t
rr
I
F
 
= I
R
 
= 100 mA
3.0
ns
I
rr
 
= 0.1 I
R
 , R
L
 
= 100 Ω
■ Electrical Characteristics  T
a
 
= 25°C ± 3°C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
 = 50 Ω
Wave Form Analyzer
(SAS-8130)
R
i
 = 50 Ω
t
p
 = 2 µs
t
r
 = 0.35 ns
δ = 0.05
I
F
 = 100 mA
I
R
 = 100 mA
R
L
 = 100 Ω
10%
Input Pulse
Output Pulse
I
rr
 = 0.1 I
R
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1 : Anode
2 : Cathode
EIAJ : SC-76
SMini2-F1 Package
1.25
±0.1
0.7
±0.1
2.5
±
0.2
1.7
±
0.1
0.4
±
0.1
0 to 0.1
(0.15)
0.16
0.5
±0.1
1
2
+0.1
–0.06
0.35
±0.1
0 to 0.1
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 1 GHz.
4. *: t
rr
 measurement circuit
Note) *: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)
Note) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).