Table 14. Alarm condition description. 
 
The description of the severity levels of the different alarms are given in 
Section 5.2.6. 
Alarm Description 
Error 
source 
Bitrate regulation in 
progress 
The regulation algorithm is working with 
bitrate estimation. 
This alarm may stay on the first minutes 
after tuning to a new IP stream. If the 
alarm does not clear, the input stream 
may be a variable bitrate stream.  
SNTP server 
unreachable 
Unit is unable to connect to SNTP 
server. 
There is no SNTP server on the 
configured IP address or there is no 
contact with the SNTP server due to 
network problems.  
No sync 
No valid ASI input stream detected. 
The problem can be related to a 
problem with the sending device or the 
cable.  
Too high 
temperature 
Internal temperature of unit is too high. 
The fans are not working or forced 
cooling is required. 
Sequence error   
Analysis of the sequence number of the 
RTP layer indicates that IP frames have 
been lost or that they have been 
received out of order 
Typically this error is generated by 
packets being dropped by some 
equipment in the network, f.ex when a 
link is overloaded. 
Defective fan 
There is an error with fan of the unit  
Hardware problem. 
No data received 
No data received on Ethernet input for 
stream 
The most likely error is that there is a 
set-up problem where IP address and 
UDP port are not correctly configured. 
The error can result from an error with 
the transmitting unit or an error on the 
network. 
No lock 
The IP receive channel is not able to 
find an initial bitrate for the data 
received. 
The stream contains a PCR PID with an 
invalid clock reference. 
Data lost 
Stream received is incomplete and a 
valid ASI output can not be expected 
See ‘Sequence errors’. If you have 
‘Sequence errors’ but not ‘Data lost’, all 
frames are received but they are out of 
sequence, or enough data is received 
for the FEC engine to correct all lost 
frames. 
ARP unresolved 
IP address not resolved into physical 
MAC address. 
This error may be caused by wrong 
default gateway configured, wrong 
unicast IP address on same subnet or 
unit on same subnet does not respond. 
Ethernet link down 
No link on Ethernet layer 
No connection on physical layer. 
Input buffer 
overflow 
The total bitrate of the IP input streams 
is too high.   
There is a configuration error or one of 
the sources is generating a too high 
bitrate.  
Output buffer 
overflow 
The total bitrate of the ASI input 
streams is too high. 
There is a configuration error or one of 
the sources is generating a too high 
bitrate.